Faculty Advisor

Johari, Hamid.

Abstract

An experiment was conducted on printed circuit board parameters with regards to the 0201 surface mounted component (.020 x .010 inches) and the defects affecting them by varying four of the process parameters. Although some of the alternative products performed just as well as those presently used by MIT Lincoln Laboratory; from a business standpoint it was recommended that the process parameters used by the laboratory remain the same; .005 inch laser cut stencil, SC3401 solder paste, and the RSS (1088) profile.

Publisher

Worcester Polytechnic Institute

Date Accepted

January 2005

Major

Mechanical Engineering

Project Type

Major Qualifying Project

Accessibility

Restricted-WPI community only

Advisor Department

Mechanical Engineering

Advisor Program

Mechanical Engineering

Share

COinS